Operation Manual ELI-EPTZ-27DN eLineTechnology.com
24
Chapter 4 Trouble Shooting of Dome Device
1.Problem description: After power on without any response, not lock motor nor
images.
Possible reason: The power circuit maybe have some problem
Solution: Check the power cable is connected to power of AC24V.
2. Problem description: After power on, the dome device rotate normally, but no
character nor image display
Possible reason: The character monitor switch is off
Solution: Switch on the character monitor according to the menu instruction
3. Problem description: After self-test of the dome device, menu cannot be displayed
Possible reason: Wrong operation
Slution:Call+95+ACK to open
4. Problem description: Distorted character or image
Possible reason: Interfered by exterior electronic signal (noise) or the camera is
directed to the monitor screen
Solution: Grounding the dome device or shut off the surrounding big electronic
devices(electric, HF, signal generating) equipment, or rotate the camera
5. Problem description: Self-test is normal, but can not control the device.
Possible reason: Wrong setting
Solution: Set the protocol, baud rate and address of dome device Check the circuit
Comentários a estes Manuais